Filter Results By:

Products

Applications

Manufacturers

Showing results: 1321 - 1335 of 1527 items found.

  • Analogue (1kV below) Insulation Tester

    1652 IN - Standard Electric Works Co., Ltd

    ● High quality Taut Band movement.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Two continuity test on “low ohms” : 3Ω & 500Ω.● AC voltmeter with linear scale up to 600 Vac.● 200mA short circuit current for continuity.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.● Live warning and display of external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● Supplied with high quality test leads.● BS 16 edition.

  • Analogue (1kV below) Insulation Tester

    8031 IN - Standard Electric Works Co., Ltd

    ● High quality Taut Band movement.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Two continuity test on “low ohms” : 2Ω & 20Ω.● AC voltmeter with linear scale up to 600 Vac.● 200mA short circuit current for continuity.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.● Live warning and display of external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● Supplied with high quality test leads.● BS 16 edition.

  • Regenerative Battery Pack Test System

    17040 - Chroma ATE Inc.

    Conforms to international standards for battery testing: IEC, ISO, UL, and GB/T, etc.Regenerative battery energy discharge (Eff. >90%, PF >0.95, I_THD <5%)Multiple voltage and current ranges for auto ranging function to provide optimum resolutionHigh accuracy current/voltage measurement (0.05%FS/0.02%FS)2ms current slew rate (-90% ~ 90%)Dynamic (current/power) driving profile simulation tests for NEDC, FUDS, HPPCTest channel parallel functionTest data analysis functionData recovery protection (after power failure)Automatic protection for error conditionBattery simulator (option)High power testing equipment- Voltage range : 80~1000V - Current range : 0~750A - Power range : 0~300kWCustomized integration functions- Integrated temperature chamber - BMS data analysis - Multi-channel voltage/temperature recording

  • OTP-Based Test System

    LXinstruments GmbH

    Power electronics assemblies often cannot be tested using conventional technology for their electrical performance. Due to the adaptability of the instrumentation, the OTP concept offers an ideal platform even beyond the space requirements of several control cabinets. In order to achieve high test flexibility with different assemblies, the system was equipped with three-phase AC sources and AC loads as well as a precise three-phase power meter. DC sources and loads with different current and voltage ranges cover the test of frequent DUT operating parameters. Time-dependent voltage or current signals can be stimulated by an arbitrary generator with power amplifier. General measurements such as current, voltage, frequency, resistance can be carried out flexibly at various test points using the matrix concept. An oscilloscope with RF multiplexer is available for high-frequency measurements such as residual ripple, switching processes, etc.

  • Testing Services

    Computec SRL

    - Laboratory of electrical tests and measurements- Injection of voltages and currents. - Megger SMRT33 Triphasic Case- Protection relay test- Tests with class 0.2 instruments - Fluke N5K 3PP50IP Norma 5000 High Precision Power Analyzer- Verification of energy meters- Fault Recorder Verification- Verification of Power Quality Analyzers- GPS verification

  • Three-Phase Relay Protection Tester

    GDJB-PC - Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd

    1.GDJB-PC Universal Secondary Injection Relay Test Set is applied to test the relay unit in relay protection system. 2.At the same time GDJB-PC Universal Secondary Injection Relay Test Set could be considered as a universal three phase AC/DC voltage source or current source. 3.It can work alone or connected to computer, inside the relay controller there are new speed digital signal mini PC and real DAC (Digital-to-Analog Converter) template with new high fidelity and high power, the machine has large panel screen and rotating mouse. It is small in volume, high precision.

  • Voltmeter According to DIN EN 61010-1 (VDE 0411-1)

    PeakTech Prüf- und Messtechnik GmbH

    An innovative graphic multimeter with a 50,000-digit color TFT display for precise measurements with a high DC basic accuracy of 0.05%. The internal data logger enables the recording of measured values, which can be recorded over a period of several hours and the transfer to a Windows PC at a later time is ensured. Internally stored measured value recordings can also be accessed and graphically displayed on the multimeter itself or on the PC. Via Bluetooth, the measured values ​​can also be displayed live via app for Android and iOS devices, recorded in a table and e.g. send by email for further processing. This multimeter has a variety of measurement functions for direct and alternating voltage measurements (incl.ACV + DCV), direct and alternating current measurements, resistance, capacitance, frequency or temperature, whereby alternating voltage and alternating current are recorded as True RMS values. Due to the extensive measurement functions and the intuitive operation, this device is ideally suited for every electronics engineer, technician and engineer who attach great importance to a precise, indestructible and technically powerful multimeter.

  • Bipolar/FET/Diode Dual Head Production Test System

    36XX - FETservice, Inc

    Two test stations on the 3600E and 3601E systems. Performs DC, AC, and pulsed tests. Excels at evaluating difficult to measure parameters on zeners, current limiters, varactor tuning diodes and darlingtons. 24 bin opto-isolated handler/prober interface. Parallel first-in first out computer to tester interface for maximum throughput. Parallel testing with a 3602E or 3603E allows shared test execution for extremely high throughput applications when interfaced to high speed handlers with multiple test sites.

  • Multi-Channel Digital Power Meters

    Chroma 66203/66204 - Chroma Systems Solutions, Inc.

    Chroma’s Digital Power Meters are designed for both single-phase and multiple phase measurements of AC power signals and related parameters common to most electronic products. Instead of traditional analog measurement circuits the 66200 Digital Power Meter uses state-of-the-art DSP digitizing technology. The internal 16 bits analog/digital converters with sampling rates of up to 200KHz provide both high speed and high accuracy measurements which is unprecedented within the industry for this class of power meters current on the market.

  • Difference Amplifiers

    Analog Devices Inc.

    A difference amplifier is a special purpose amplifier designed to measure differential signals, otherwise known as a subtractor. A key feature of a difference amplifier is its ability to remove unwanted common mode signals, known as common mode rejection (CMR). Unlike most types of amplifiers, difference amplifiers are typically able to measure voltages beyond the supply rails, and are used in applications where large dc or ac common-mode voltages are present. They are ideal for current and voltage monitoring. Analog Devices offers a range of difference amplifiers, optimized for low distortion, low power, or high voltage performance.

  • Digital Panel Meter

    Nippen Electrical Instruments Co.

    To be supplied with the right meter, simply furnish the following details in your order: Model Number, Description of the Meter. Accuracy Class. Voltage Input (110 Volts from PT, 240 Volts line to neutral or 415 Volts Line to Line). PT Ratio specifies the High Voltage Primary first ( 33 kV.110V). Current input (5Amps or 1 Amp secondary ) CT ratio (e.g. 100/5 Amps. etc.). Aux. Supply : 50/60 Hz (240VAC of 110/VAC). Dimension : 96 x 96mm or 48 x 96 mm or 144 x 144 mm.

  • ECT / ECA Eddy Current Flaw Detector

    EVi - United Western Technologies Corp

    The EVi works directly with the EddyView Family of probes and accessories. UniWest’s unmatched selection of standard and advanced display features set a new standard for flexibility of applications, ease of use, interpretation of data and overall operator accuracy. The key to the EVi’s ground-breaking performance is the display of a visual image of the surface area under inspection alongside the customary and selectable eddy current signal displays (impedance plane, A-scan or strip charts). The EVi provides a high precision, easily readable display of surface conditions enabling improved interpretation of data while giving more accurate discernment of cracks, pits, gouges and fretting.

  • Electrochemistry Research Equipment

    NuVant Systems, Inc.

    Our electrochemical equipment will help your group achieve laboratory and research goals. The best-selling EZstat Pro potentiostat/galvanostat can run cyclic voltammetry, electrochemical impedance spectroscopy (EIS), battery tests, and high speed galvanostatic intermittent titration technique (GITT). The EZstat HV potentiostat delivers up to 1 amp at 25 volts. The Powerstat comes in two configurations (5 amp vs 20 amp). The Duostat bipotentiostat can operate rotating ring-disk electrode experiments. The Arraystat and ArrayPGstat feature multichannel operation with different customizable options (current range, number of channels, etc.).

  • Rad Hard GaN Drivers

    Renesas Electronics Corp.

    The space market has been driving towards more efficient power management solutions. Part of the drive includes the use of Gallium Nitride Field Effect Transistors (GaN FETs) for power conversion. GaN FETs have higher power conversion efficiency and have more natural immunity to radiation, due to them being wide-bandgap semiconductors. Equally important is the use of the correct driver that will allow reliable operation and maximize the benefits of the GaN FETs. Some of the key driver requirements are: a well-regulated gate drive voltage; high source/sink current capability and a split driver output stage.

  • DM 150-Watt Transmitter

    Loc-150Tx - Vivax-Metrotech Corp

    The Loc-150Tx, 150-Watt DM Transmitter is used primarily with the Defect Mapper (DM) Receiver, however it is also useful for those needing a low frequency, high output transmitter. Typically, the Loc-150Tx, transmitter (DM transmitter) is used to apply a signal current to the anode bed. The pipeline returns the signal via coating faults back to the transmitter. The Loc-150Tx transmitter is designed to be powered from CP (Cathodic Protection) stations, AC or external batteries, eliminating the need for internal batteries. This transmitter has a direct connection mode to apply the locate frequency onto the conductor.  There is no clamp or induction mode.

Get Help